Diagnostics and Troubleshooting
296 809480 Instruction Manual XPR300
716
Error
Process Invalid 5: not allowed or system
not ready
The cutting system is not
ready for a new process ID.
It can only accept a process
ID during the following
states: “Initial Checks (2),”
“Inert Gas Purge (4),” “Wait
for Start (5),” “Manual Leak
Test (20)” or “End of Cycle
(14)” states.
Wait until gas purge or cutting is complete. The
cutting system cannot accept a new process ID
during gas purge or cutting.
If the code continues, contact your cutting machine
supplier or regional Hypertherm Technical Service
Team.
None Set process;
remote on-off
6: not supported
The 3 XPR gas connect
consoles (OptiMix, VWI,
Core) can have different
capabilities. For example,
argon assist and argon
marking for mild steel are
available for cutting systems
equipped with OptiMix or
VWI gas connect consoles,
but not with Core.
Refer to How to choose the torch positions and
process settings you need on page 217. for
information about different process capabilities.
None Set process;
remote on-off
717
Alert
(OptiMix only)
Low voltage-mix The supply voltage for the
gas mixer in the gas connect
console is less than 21 V.
Confirm the output voltage of the 24 VDC power
source in the gas connect console. The output
voltage should be 24 VDC.
Ramp down Set process;
remote on-off
718
Alert
High voltage-mix The supply voltage for the
gas mixer in the gas connect
console is more than 27 V.
Ramp down Set process;
remote on-off
Diagnostic code
number and
category
Diagnostic code
name
Description Corrective action XPR action
Code cancels
with