Diagnostics and Troubleshooting
8
338 809480 Instruction Manual XPR300
b. Review the diagnostic code history for previous pressure-related codes that can indicate
where to look for flow or pressure problems.
c. If you identify a code for a pressure transducer (P1 or P2), exchange the transducers. See if
the code follows the transducer change. Replace the bad transducer if necessary. For
instructions, refer to “Replace a pressure transducer” in the XPR Replacement Parts
Procedures Field Service Bulletin (809970).
4. If you have a cutting system equipped with a OptiMix gas connect console, refer to Process-gas
inlet pressure in the torch connect console diagnostic codes (702, 705, 769, 770) for
OptiMix-equipped cutting systems on page 334.
5. If you have a Core or VWI gas connect console, or if the code continues, or if you cannot find or
resolve the problem with these corrective actions, contact your cutting machine supplier or
regional Hypertherm Technical Service team.
How to do a gas leak test (VWI and OptiMix)
NOTICE
INCORRECT GAS PRESSURES CAN CAUSE BAD PERFORMANCE
Gas leaks or pressure and flow rates that are outside of recommended ranges can:
Cause problems with system performance
Result in bad cut quality
Shorten the life of consumables
If the quality of the gas is bad or if the pressure setting is incorrect, it can decrease:
•Cut quality
Cut speed
Cut thickness capabilities

Table of Contents

Other manuals for Hypertherm XPR300

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm XPR300 and is the answer not in the manual?

Hypertherm XPR300 Specifications

General IconGeneral
Cutting Current300 A
Duty Cycle100% at 300 A
TechnologyX-Definition Plasma
Gas SupplyOxygen, Nitrogen, Air
Cutting Capacity (Mild Steel)38 mm (1.5 in)
Severance Capacity (Mild Steel)75 mm (3 in)
Pierce Capacity (Mild Steel)50 mm (2 in)
Input Voltage200–480 V, 3-PH, 50/60 Hz