9-5
■ Fine programmed scan/fine ∂F scan
In fine scan (programmed or ∂F), the scan speed de-
creases when the squelch opens, but the transceiver
keeps scanning. The scanning tuning step shifts from
50 Hz to 10 Hz when the squelch opens.
[F-2•∂F][F-1•PROG] [F-3•FINE] [EXIT/SET]
q Push [EXIT/SET] several times to close a multi-func-
tion screen, if necessary.
wPush[F-5•SCAN]toselectthescanscreen.
e Set for programmed scan or ∂F scan as described
on previous page.
rPush[F-1•PROG]or[F-2•∂F] to start a scan.
• “ ” or “ ” and decimal points
blink while scanning.
tPush[F-3•FINE]tostartafinescan.
•“ ” or “ ” blinks instead
of “
” or “ ,” respectively.
y When the scan detects a signal, the scan speed de-
creases but scan does not stop.
uPush[F-1•PROG]or[F-2•∂F] to stop the scan; push
[F-3•FINE]tocancelthefinescan.
•Rotatingthemaindialalsocancelsthescan.
iHolddown[F-6•RECALL]for1secondtorecallthe
frequency that is set before starting the scan, if de-
sired.
9
SCANS