14-3
D Command table
14
CONTROL COMMAND
Cmd.
Sub Cmd.
Data Description
00
see p. 14-10
Send frequency data (transceive)
01
see p. 14-10
Send mode data (transceive)
02
see p. 14-12
Read band edge frequencies
03
see p. 14-10
Read operating frequency
04
see p. 14-10
Read operating mode
05
see p. 14-10
Set operating frequency
06
see p. 14-10
Operating mode selection for trans-
ceive
07
SelectVFOmode
B0 Exchange main and sub bands
B1 Equalize main and sub bands
C0 Turn the dualwatch OFF
C1 Turn the dualwatch ON
D0 Select main band
D1 Select sub band
08
Select memory mode
0001 to
0099
Select memory channel
(0001=M-CH01, 0099=M-CH99)
0100 Select program scan edge channel P1
0101 Select program scan edge channel P2
09
Memory write
0A
MemorytoVFO
0B
Memory clear
0E
00 Scan stop
01 Programmed/memory scan start
02 Programmed scan start
03
F scan start
12 Fine programmed scan start
13
Fine F scan start
22 Memory scan start
23 Select memory scan start
A1
Select F scan span ±5 kHz
A2
Select F scan span ±10 kHz
A3
Select F scan span ±20 kHz
A4
Select F scan span ±50 kHz
A5
Select F scan span ±100 kHz
A6
Select F scan span ±500 kHz
A7
Select F scan span ±1 MHz
B0 Set as non-select channel
B1 Set as select channel
(ThepreviouslysetnumberbyCI-Vis
set after turning power ON, or “1is
selected if no selection is performed.)
01
Set as select channel “1”
02
Set as select channel “2”
03
Set as select channel “3”
B2 00 Set “ALL” for select memory scan
01
Set “1” for select memory scan
02
Set “2” for select memory scan
03
Set “3” for select memory scan
D0 Set scan resume OFF
D3 Set scan resume ON
0F Read split setting
(00=OFF, 01=ON)
00 Turn the split function OFF
01 Turn the split function ON
Cmd.
Sub Cmd.
Data Description
10
00 Send/read tuning step OFF
01 Send/read 100 Hz tuning step
02 Send/read 1 kHz tuning step
03 Send/read 5 kHz tuning step
04 Send/read 9 kHz tuning step
05 Send/read 10 kHz tuning step
06 Send/read 12.5 kHz tuning step
07 Send/read 20 kHz tuning step
08 Send/read 25 kHz tuning step
11
00 Send/read attenuator OFF
03 Send/read 3 dB attenuator
06 Send/read 6 dB attenuator
09 Send/read 9 dB attenuator
12 Send/read 12 dB attenuator
15 Send/read 15 dB attenuator
18 Send/read 18 dB attenuator
21 Send/read 21 dB attenuator
12 00 00, 01 Select/read ANT1 selection
(00=RX ANT OFF; 01=RX ANT ON)
01 00, 01 Select/read ANT2 selection
(00=RX ANT OFF; 01=RX ANT ON)
02 00, 01 Select/read ANT3 selection
(00=RX ANT OFF; 01=RX ANT ON)
03 00 Select/read ANT4 selection
(00=RX ANT OFF; fix)
13 00 Announce all data with voice synthe-
sizer
01 Announce frequency and S-meter
level with voice synthesizer
02 Announce receive mode with voice
synthesizer
14 01 0000 to
0255
Send/read [AF] level
(0000=max. CCW, 0255=max. CW)
02 0000 to
0255
Send/read [RF] level
(0000=max. CCW, 0255=max. CW)
03 0000 to
0255
Send/read [SQL] level
(0000=max. CCW, 0255=max. CW)
05 0000 to
0255
Send/read [APF] level
( 0000=Pitch–550 Hz, 0128=Pitch,
0255=Pitch+550 Hz; 10 Hz steps)
06 0000 to
0255
Send/read [NR] level
(0000=0%, 0255=100%)
07 0000 to
0255
Send/read inner [TWIN PBT] position
( 0000=max. CCW, 0128=center,
0255=max. CW)
08 0000 to
0255
Send/read outer [TWIN PBT] position
( 0000=max. CCW, 0128=center,
0255=max. CW)
09 0000 to
0255
Send/read CW pitch
( 0000=300 Hz, 0128=600 Hz,
0255=900 Hz; 5 Hz steps)
0A 0000 to
0255
Send/read [RF PWR] position
(0000=max. CCW, 0255=max. CW)
0B 0000 to
0255
Send/read [MIC] position
(0000=max. CCW, 0255=max. CW)
0C 0000 to
0255
Send/read [KEY SPEED] level
(0000=6 wpm, 0255=48 wpm)
0D 0000 to
0255
Send/read [NOTCH] position
( 0000=max. CCW, 0128=center,
0255=max. CW)
0E 0000 to
0255
Send/read COMP level
(0000=0, 0255=10)
0F 0000 to
0255
Send/read [DELAY] position
(0000=max. CCW, 0255=max. CW)