MENU SCREEN
12-35
AlarmSelect (Default:OFF)
GPS > GPS Alarm> Alarm Select
Select the target position(s) for the GPS alarm func-
tion.
• OFF: Turns OFF the function.
• RX: When a target (the last received position)
enters in your active alarm range, the GPS
alarm sounds.
• Group: When a target (positions in the GPS mem-
ory, or in the selected GPS memory group)
enters in your active alarm range, the GPS
alarm sounds.
• Memory: When a target (the specied position in the
GPS memory) enters in the active alarm
range, the GPS alarm sounds.
AlarmArea(Group) (Default:0.25')
GPS > GPS Alarm> Alarm Area (Group)
Set the GPS active alarm range.
When the “Alarm Select” item is set to “Group,this set-
ting is enabled.
When a target enters in the specified active alarm
range, the GPS alarm sounds and the GPS alarm icon
blinks.
The programmable values depend on the setting in Po-
sition Format.
• Position Format = dddºmm.mm' 00.08' to 59.99'
(0.01' steps)
• Position Format = dddºmm'ss'' 00'05'' to 59'59''
(0’01" steps)
Example:
When a target enters in the active alarm range, the
GPS alarm sounds and the GPS alarm icon blinks.
0.25’ 0.25’
0.25’0.25’
N
Your
position
Point A
Point B
Point C
(Beeps three times)
AlarmArea(RX/Memory) (Default:Both)
GPS > GPS Alarm> Alarm Area (RX/Memory)
Select the GPS active alarm range.
When the “Alarm Select” item is set to “RX” or “Memo-
ry, this setting is enabled.
When a target enters in the active alarm range, the
GPS alarm sounds and the GPS alarm icon blinks.
• Limited : The transceiver sounds 3 beeps and the
GPS alarm icon blinks when the target en-
ters the 500 meter range.
• Extended : The transceiver sounds 3 beeps and the
GPS alarm icon blinks when the target en-
ters the 1 kilometer range.
• Both : The transceiver sounds a beep and the
GPS alarm icon blinks when the target
enters the 1 kilometer range, and sounds
3 beeps and the icon blinks when it enters
the 500 meter range.
When the target exits the 500 meter range,
but is still in the 1 kilometer range, the icon
continues to blink, but no beeps sound.
Example:
When a target enters in the active alarm range (500
meter or 1 kilometer range, depending on the setting),
the GPS alarm sounds and the GPS alarm icon blinks.
Your
position
Extended range
(Approximately 1 km/1094 Y)
Limited range
(Approximately 500 m/547 Y)
Beeps one times Beeps three times