MENU SCREEN
12-61
BeepLevel (Default:9)
Sounds > Beep Level
Set the beep audio output level to between 0 (OFF), 1
(minimum) and 9 (maximum).
Key-TouchBeep (Default:ON)
Sounds > Key-Touch Beep
Turn the confirmation beep tones ON or OFF.
• OFF: No beep sounds.
• ON: A beep sounds when you touch a screen.
HomeCHBeep (Default:ON)
Sounds > Home CH beep
Turn the Home CH Beep ON or OFF.
• OFF: No beep sounds.
• ON: Sounds a beep when you select the Home CH
by rotating [DIAL].
NOTE: You can set a Home CH for the VFO mode,
Memory mode and the DR function. (p. 2-16)
BandEdgeBeep (Default:OFF)
Sounds > Band Edge Beep
Turn the Band edge beep ON or OFF.
• OFF: No beep sounds.
• ON: A beep sounds when you tune into or out of the
AIR, VHF and UHF band’s frequency range by
rotating [DIAL].
ScanStopBeep (Default:OFF)
Sounds > Scan Stop Beep
Turn the scan stop beep ON or OFF.
• OFF: No beep sounds.
• ON: A beep sounds when a scan stops by receiving
a signal.
StandbyBeep (Default:ON(tome:HighTone))
Sounds > Standby Beep
Turn the standby beep function ON or OFF.
This function sounds a beep after a received signal dis-
appears, in the DV mode.
• OFF: Turns OFF the function.
• ON: Sounds a beep after a received signal disap-
pears.
• ON (to me: High Tone):
Sounds a beep after a received signal disap-
pears.
If the signal is addressed to your call sign, a
higher tone beep sounds.
The standby beep sounds even when the “Key-
touch beep” is set to “OFF.
You can set the standby beep output level with the
“Beep level” item.
SubBandMute (Default:OFF)
Sounds > Sub Band Mute
Select whether or not to mute the SUB band audio sig-
nal while receiving on the MAIN band, and/or sound a
beep when a signal disappears on the SUB band.
• OFF: Disables the SUB band mute function.
• Mute: While receiving on the MAIN band, the
SUB band audio signal is muted.
• Beep:
When a signal disappears on the SUB
band, a beep sounds.
The beep sounds even if no signal is
received on the MAIN band.
• Mute & Beep: While receiving on the MAIN band, the
SUB band audio signal is muted.
While receiving on the SUB band, and
a signal disappears, a beep sounds.
- The beep sounds even if no signal is re-
ceived on the MAIN band.
Scope AF Output (Default:ON)
Sounds > Scope AF Output
Select the audio output option during a sweep by the
Band Scope function.
• OFF: No audio is heard during the sweep.
• ON: Audio is heard during the sweep.
• Only when the dual watch mode is selected.