17
MAINTENANCE
17-3
Resetting the CPU (Continued)
D All reset
NOTEfortheAllreset:
After you perform an All reset, you cannot use the DR
function because the repeater list will be cleared.
So we recommend you save the programmed data
onto an SD card, or to your PC using the CS-5100
cloning software (contained in the CD) before per-
forming an All reset.
After the All reset is finished, load or write the saved
data into your transceiver.
Touch [MENU]. q
Touch “All Reset. w
( Others > Reset > All Reset)
If the item is not displayed, touch [] or [] one or more
times to select the page.
Touch “NEXT. e
Touch “YES. r
After the All reset is nished, the default screen is dis-
played.
AfteranAllreset
An all reset clears all programming, and returns all set-
tings to their factory defaults.
Therefore, the repeater list, Memory channel contents,
filter settings and so on will be cleared, so you will need
to reenter your memories, list and operating settings.
WhenyoucannotentertheSetmode
If a touch screen error or an unexpected operation oc-
curs, you may not be able to enter the Menu screen. In
this case, perform the All reset, as described below:
While holding down the reset button on the controller
back panel, push [ ] to turn power ON.
Reset button
Previous view