10
SCAN OPERATION
10-8
VFO Scan
DSetting the Program Link function
[MENU] > SET > Scan > Program Link
1� Push [MENU]�
2� Select “Scan” in the “SET” menu�
3� Select “Program Link�”
4� Select a Program Link number “0” ~ “9�”
The Program Link Number screen displays the
preregistered Program Scan ranges�
L When no Program Scan range is selected, “– Blank –”
is displayed�
5� Push [QUICK]�
6� Select “Add�”
7� Select the Program Scan range that you want to add�
8� Repeat steps 6 and 7 until all Program scan ranges that
you want are added�
9� Push [ENT] to save the Program Link�
L To exit the MENU screen, push [MENU]�
TIP:
To edit the name of the Program Link, push [QUICK]
and select “Edit Name” at above step 4�
To delete the registered Program Scan range from the
Program Link, select “Delete” at above step 6�
DAbout the Program Link Scan
This item sets the Link function for 2 or more
Program Scan ranges to sequentially scan during a
Program Link scan� The Program Link scan scans all
frequencies in the scan ranges�
Example settings of the Program Link
...
Program Link 0
1
9
Edit Name
01 144.000−440.000
Program Link number (0 to 9)
Blank
Delete
Program Scan
lower edge
Program Scan
upper edge
L Information
The Program Link Number screen displays the frequency
range�
You can add a Link setting by pushing [QUICK] when 2 or
more Program Scan ranges (P-Scan Edge) are entered�
When there is no Program Scan range (P00 ~ P24)
entered, “Add” is not displayed after pushing [QUICK]�
Program Scan range (p� 10-7)