15
OTHER FUNCTIONS
15-3
Band Scope function
NOTE: During the continuous sweep, the noise may
occur if you bring your hand or body close to the
screen�
DUsing the Band Scope function
[MENU] > SCOPE
1� Push [MENU]�
2� Select “SCOPE�”
Returns to the standby screen, and starts the
continuous sweep�
3� Push [QUICK]�
4� Select “Scope Mode�”
5� Select the Band Scope display mode�
Displays the selected display mode, and starts the
continuous sweep�
6� Push [ENT]�
Stops the sweep�
L Push [ENT] again, to resume the sweep for the
Continuous Sweep function�
7� When the sweeping stops, rotate [DIAL] to move
the sweep marker to a detected signal�
You can hear the signal audio�
L While the sweep is paused, push [CLR] to turn OFF
the Band Scope function�
Band Scope screen operation
Key Action
[DIAL] Rotate to select an operating frequency
D-pad()
Push to cancel the Band Scope zone
selection�
D-pad()
Push to select the Band Scope zone (with a
line in orange)�
[ENT] Push to start or stop a sweep�
[QUICK]
Push to open the Quick Menu window
L When selecting the Band Scope zone,
only the Band Scope menu is displayed�
[CLR]
When selecting the Band Scope zone:
Push to stop the sweep during a sweep�
Push to turn OFF the Band Scope
function while stopping a sweep�
DUsing the Waterfall display
On the single band display, you can turn the waterfall
display ON or OFF
TIP:
If the tuning step is set too wide, the signals in the
sweep range may not be displayed (they may be
skipped), even if they are strong signals� Therefore,
we recommend that you set the tuning step to 20 kHz
or less to use the Band Scope function� See the Basic
manual Section 3 for details on how to set the tuning
step�
On the AIR band, you cannot hear the displayed
frequency’s audio during a sweep� When “AF Output
(DUAL/AIR Band)” is set to ON, the received audio is
momentarily output during a sweep, and you will know
that a signal is received without looking at the display
- You can turn “AF Output (DUAL/AIR Band)” ON or
OFF on the MENU screen� (p� 12-30)
-
The FM Radio audio output may be interrupted due to
the AF Output (DUAL/AIR Band) function� In that case,
set “AF Output (DUAL/AIR Band)” to OFF, or set “Auto
Mute” to OFF
([MENU] > SET > Scope > AF Output (DUAL/AIR Band))
([MENU] > FM RADIO > FM Radio Set > Auto Mute)
L Information
Higher signal levels are Red, Yellow, Green, Light-blue,
Blue, and Black (no signal), in that order
During a sweep, the scales on both sides of the waterfall
zone are moved with the waterfall� While stopping a
sweep, the scales and the waterfall also freeze�
You can select the Waterfall speed�
([MENU] > SET > Scope > Waterfall Speed)
Waterfall
zone
Scale Scale
When selecting a
Band Scope zone
(with a line in orange)