EasyManua.ls Logo

IEMCA BOSS 545 E - Page 116

Default Icon
211 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5 - ADJUSTMENTS AND SETTING-UP BOSS 332/545/552 HD
EN
5 - Pag. 31 / 34
5.4 CAM BOX - TIMING
If the bar feeder is equipped with a cam box, each cam should be timed to its own microswitch.
The timing procedure is as follows.
MICROSWITCH FUNCTION
S90 - Bar feeding enabling signal
It controls the bar feeding motor start/stop. It must be operated at each collet opening. In
addition, it also controls operation of the bar-headstock synchronization device.
S91 - Bar change enabling
It signals lathe collet opening/closing to the bar feeder.
It determines the camshaft stop position at bar end.
S92 - Feeding stop enabling
Only used in sliding headstock lathes. It disables the bar feeder feeding thrust during any
operations requiring headstock return with closed collet.
S99 - Camshaft stop
It determines the camshaft stop position when there is no thread (connected in series with a
microswitch or relay located on the lathe).