Parameter List
‑24‑
Parame
ter
Address Name Value Range Default Unit Change
Method
Page
F4‑29 0xF41D Percentage
corresponding to
pulse minimum
input
‑100.0% to +100.0% 0 % In real time "
F4‑29
"
on
page 180
F4‑30 0xF41E Pulse maximum
input
F4‑28 to 100.00 kHz 50 kHz In real time "
F4‑30
"
on
page 180
F4‑31 0xF41F Percentage
corresponding to
pulse maximum
input
‑100.0% to +100.0% 100 % In real time "
F4‑31
"
on
page 180
F4‑32 0xF420 Pulse filter time 0.00–10.00s 0.1 s In real time "
F4‑32
"
on
page 181
F4‑33 0xF421 AI curve selection Ones: AI1
1: Curve 1 (2 points, see F4‑13
to F4‑16)
2: Curve 2 (2 points, see F4‑18
to F4‑21)
3: Curve 3 (2 points, see F4‑23
to F4‑26)
4: Curve 4 (4 points, see A6‑00
to A6‑07)
5: Curve 5 (4 points, see A6‑08
to A6‑15)
Tens: AI2
1: Curve 1 (2 points, see F4‑13
to F4‑16)
2: Curve 2 (2 points, see F4‑18
to F4‑21)
3: Curve 3 (2 points, see F4‑23
to F4‑26)
4: Curve 4 (4 points, see A6‑00
to A6‑07)
5: Curve 5 (4 points, see A6‑08
to A6‑15)
0x321 ‑ In real time "
F4‑33
"
on
page 181
Contin
ued
Contin
ued
Continued Hundreds: AI3
1: Curve 1 (2 points, see F4‑13
to F4‑16)
2: Curve 2 (2 points, see F4‑18
to F4‑21)
3: Curve 3 (2 points, see F4‑23
to F4‑26)
4: Curve 4 (4 points, see A6‑00
to A6‑07)
5: Curve 5 (4 points, see A6‑08
to A6‑15)
Contin
ued
Contin
ued
Continued Continued