EasyManua.ls Logo

Inovance MD500-PLUS Series - Page 26

Inovance MD500-PLUS Series
718 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter List
‑25‑
Parame
ter
Address Name Value Range Default Unit Change
Method
Page
F4‑34 0xF422 Setting for AI lower
than the minimum
input
Ones (position): AI1
0: Percentage corresponding
to minimum input
1: 0.0%
Tens (position): AI2
0: Percentage corresponding
to minimum input
1: 0.0%
Hundreds (position): AI3
0: Percentage corresponding
to minimum input
1: 0.0%
0 In real time "
F4‑34
"
on
page 181
F4‑35 0xF423 DI1 delay 0.0s to 3600.0s 0 s In real time "
F4‑35
"
on
page 182
F4‑36 0xF424 DI2 delay 0.0s to 3600.0s 0 s In real time "
F4‑36
"
on
page 182
F4‑37 0xF425 DI3 delay 0.0s to 3600.0s 0 s In real time "
F4‑37
"
on
page 183
F4‑38 0xF426 DI valid mode
selection 1
Ones: DI1 valid mode
selection
0: Active high
1: Active low
Tens: DI2 valid mode selection
0: Active high
1: Active low
Hundreds: DI3 valid mode
selection
0: Active high
1: Active low
Thousands: DI4 valid mode
selection
0: Active high
1: Active low
Ten thousands: DI5 valid
mode selection
0: Active high
1: Active low
0 At stop "
F4‑38
"
on
page 183