Parameter List
‑23‑
Parame
ter
Address Name Value Range Default Unit Change
Method
Page
F4‑14 0xF40E Percentage
corresponding to
AI curve 1
minimum input
‑100.0% to 100.0% ‑100 % In real time "
F4‑14
"
on
page 175
F4‑15 0xF40F AI curve 1
maximum input
F4‑13 to 10.00 V 10 V In real time "
F4‑15
"
on
page 175
F4‑16 0xF410 Percentage
corresponding to
AI curve 1
maximum input
‑100.0% to 100.0% 100 % In real time "
F4‑16
"
on
page 176
F4‑17 0xF411 AI1 fitter time 0.00s to 10.00s 0.1 s In real time "
F4‑17
"
on
page 176
F4‑18 0xF412 AI curve 2
minimum input
–10.00 V to F4‑20 ‑10 V In real time "
F4‑18
"
on
page 176
F4‑19 0xF413 Percentage
corresponding to
AI curve 2
minimum input
‑100.0% to +100.0% ‑100 % In real time "
F4‑19
"
on
page 177
F4‑20 0xF414 AI curve 2
maximum input
F4‑18 to 10.00 V 10 V In real time "
F4‑20
"
on
page 177
F4‑21 0xF415 Percentage
corresponding to
AI curve 2
maximum input
‑100.0% to +100.0% 100 % In real time "
F4‑21
"
on
page 177
F4‑22 0xF416 AI2 fitter time 0.00s to 10.00s 0.1 s In real time "
F4‑22
"
on
page 177
F4‑23 0xF417 AI curve 3
minimum input
–10.00 V to F4‑25 ‑10 V In real time "
F4‑23
"
on
page 178
F4‑24 0xF418 Percentage
corresponding to
AI curve 3
minimum input
‑100.0% to +100.0% ‑100 % In real time "
F4‑24
"
on
page 178
F4‑25 0xF419 AI curve 3
maximum input
F4‑23 to 10.00 V 10 V In real time "
F4‑25
"
on
page 178
F4‑26 0xF41A Percentage
corresponding to
AI curve 3
maximum input
‑100.0% to +100.0% 100 % In real time "
F4‑26
"
on
page 179
F4‑27 0xF41B AI3 filter time 0.00s to 10.00s 0.1 s In real time "
F4‑27
"
on
page 179
F4‑28 0xF41C Pulse minimum
input
0.00 kHz to F4‑30 0 kHz In real time "
F4‑28
"
on
page 179