Chapter 6 — Setting Up the Printer
56 EasyCoder PM4i Printer User’s Guide (Fingerprint Version)
Stop Bits
The number of stop bits specifies how many bits will define the
end of a character. There are two options:
•1 (default)
•2
Flow Control
RTS/CTS is a protocol where the communication is controlled
by currents through separate lines in the cable being set either to
high or low. This option is disabled by default.
RTS high indicates that the transmitting unit is able to receive
characters.RTS low indicates that the receive buffer is filled to
75% (see XON/XOFF).
CTS high indicates that the unit transmitting the CTS signal is
ready to receive data. CTS low indicates that the receive buffer is
full (see XON/ XOFF). In some computer programs, for example
MS Windows Terminal, RTS/CTS is designated “Hardware.
ENQ/ACK is a protocol where the communication is controlled
by the control characters ENQ (ASCII 05 dec.) and ACK (ASCII
06 dec.) being transmitted on the same line as the data. The
sending unit transmits
ENQ at regular intervals. If the response ACK is not received, the
transmission is held up awaiting an ACK character from the
receiving unit. By default, ENQ/ACK is disabled.
XON/XOFF is a protocol where the communication is
controlled by the control characters XON (ASCII 17 dec.) and
XOFF (ASCII 19 dec.) being transmitted on the same line as the
data. XON/XOFF can be enabled/disabled separately for data
received from the host by the printer (printer sends XON/XOFF)
and for data transmitted to the host from the printer (host sends
XON/XOFF).
XOFF is sent from the printer when its receive buffer is filled to
75%, and the transmission from the host is held, waiting for an
XON character.

Table of Contents

Other manuals for Intermec EasyCoder PM4i

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intermec EasyCoder PM4i and is the answer not in the manual?

Intermec EasyCoder PM4i Specifications

General IconGeneral
Print technologyDirect thermal
Maximum resolution203 x 203 DPI
DisplayLCD
Product colorSilver
Standard interfacesRS-232, USB 2.0
Internal memory16 MB
Media thickness2.5/8.7 mm
Maximum label width114.3 mm
Maximum label length4 m
Maximum roll diameter213 mm
Maximum internal memory1 GB
Supported network protocolsTCP/IP, LPR/LPD, FTP, BOOTP, DHCP, HTTP, SNMPv3, SMTP, SNMP-MIB II
Power requirements90 - 265 VAC, 45 - 65Hz
Power consumption (standby)15 W
Power consumption (printing)125 W
Storage temperature (T-T)-20 - 70 °C
Operating temperature (T-T)40 - 104 °F
Operating relative humidity (H-H)20 - 80 %
Weight and Dimensions IconWeight and Dimensions
Depth543 mm
Width298 mm
Height261 mm
Weight13500 g