Chapter 10 — Troubleshooting
90 EasyCoder PM4i Printer User’s Guide (Fingerprint Version)
Intermec Ready-to-Work Indicator
The readiness of the printer, individually or as a part of a
solution, is indicated by the blue Intermec Ready-to-Work
Indicator (IRI).
If the IRI blinks or is switched off, the printer is not ready.
Further information can be obtained in the display window by
pressing the F5/i key. In case of several errors or similar
conditions occurring simultaneously, only the most significant
error is displayed. Once this error has been cleared, next
remaining error is displayed.
The printer will also return error messages to the host, provided
there is a working two-way communication. Refer to the Intermec
Fingerprint Developer’s Guide (P/N 934-019-XXX).
Provided the printer is connected to a network, all conditions
that prevents printing are reported to the Easy ADC Console.
The Easy ADC Console is a PC-based software which allows a
supervisor to monitor all connected devices that have an
Intermec Ready-to-Work, including handheld computers, access
points, and printers.
Display Messages and LED Indications
Error/Event RtW
Error
No.
Comment
Operational On 0 No error
Out of paper Blink 1005
Next label not
found
Blink 1031
Label not taken Blink
Out of transfer
ribbon
Blink 1027
Transfer ribbon is
installed
Blink 1058
Head lifted Blink 1022
Cutter does not
respond
Blink 1059
Cutter error1 Blink 1701
Cutter error2 Blink 1702