FETCh & MEASure Subsystem
Copyright © ITECH Electronic Co., Ltd. 36
FETCh[:SCALar]:VOLTage[:AC][:AMPLitude]:MAXimum:HOLD:CLEar
MEASure[:SCALar]:VOLTage[:AC][:AMPLitude]:MAXimum:HOLD:CLEar
This command is used to clear the single-phase voltage peak hold value.
Note: this command parameter is optional. If there is no parameter, it will return
the value of A, B, C three-phase by default.
Syntax:
FETCh[:SCALar]:VOLTage[:AC][:AMPLitude]:MAXimum:HOLD:CLEar
MEASure[:SCALar]:VOLTage[:AC][:AMPLitude]:MAXimum:HOLD:CLEar
Arguments
[A|B|C]
Returns:
<NRf>…
Example
FETCh:VOLTage:MAXimum:HOLD:CLEar
FETCh[:SCALar]:CURRent:CFACtor?
MEASure[:SCALar]:CURRent:CFACtor?
This command is used to read the current crest factor values of A, B, C
three-phase.
Note: this command parameter is optional. If there is no parameter, it will return
the value of A, B, C three-phase by default.
Syntax:
FETCh[:SCALar]:CURRent:CFACtor? [A|B|C]
MEASure[:SCALar]:CURRent:CFACtor? [A|B|C]
Arguments
[A|B|C|CH1|CH2|CH3]
Returns:
<NRf>…
Example
FETC:CURR:CFAC?