Load Protect Subsystem
Copyright © ITECH Electronic Co., Ltd. 58
Returns:
0|1|OFF|ON
Example
CURRent:PEAK:PROTection:STATe 1 //设置峰值保护状态为开启状态.
[SOURce:]CURRent:PEAK:PROTection[:LEVel] <NRf+>
The command sets the protection value of current peak protection, unit: A.
Syntax:
CURRent:PEAK:PROTection[:LEVel] <NRf+>
Arguments
<MINimum-MAXimum>
Query syntax:
CURRent:PEAK:PROTection[:LEVel]? [MAXimum|MINimum]
Returns:
MAXimum|MINimum|DEFault
Example
CURRent:PEAK:PROT 30
[SOURce:]CURRent:PEAK:PROTection:DELay <NRf+>
Set the peak current protection delay time, the unit is: s
Syntax:
CURRent:PEAK:PROTection:DELay <NRf+>
Arguments
MAXimum|MINimum|DEFault
Query syntax:
CURRent:PEAK:PROTection:DELay?
Returns:
[MAXimum|MINimum]
Example
CURRent:PEAK:PROTection:DELay 1