SOURce Subsystem
Copyright © ITECH Electronic Co., Ltd. 63
Example
FUNC CC
[SOURce:]FUNCtion:CATalog?
This command is used to query the supports load mode.
Syntax:
[SOURce:]FUNCtion:CATalog?
Arguments
AC: CC|CR|CP|CS|CC+CR|CE
DC: CC|CR|CP|CV|CC+CV|CR+CV|CP+CV|CR+CC|CC+CR+CP+CV
Arguments
AC: CC|CR|CP|CS|CC+CR|CE
DC: CC|CR|CP|CV|CC+CV|CR+CV|CP+CV|CR+CC|CC+CR+CP+CV
Example
FUNC:CAT? //query the load mode catalog
[SOURce:]UPFactor[:STATe] <Boolean>
This command is used to set state of UPF (Unit Power Factor)
Syntax:
UPFactor[:STATe] <Boolean>
Arguments
<0|1|OFF|ON>
Query syntax:
UPFactor[:STATe]?
Returns:
<0|1|OFF|ON>
Example
UPFactor 1
[SOURce:]CURRent[:LEVel][:IMMediate][:AMPLitude][:A
C] <NRf+>[,NRf+][,NRf+]
Set and query the upper limit of RMS current.