FETCh & MEASure Subsystem
Copyright © ITECH Electronic Co., Ltd. 42
Note: this command parameter is optional. If there is no parameter, it will return
the value of A, B, C three-phase by default.
Syntax:
FETCh[:SCALar]? [A|B|C]
MEASure[:SCALar]? [A|B|C]
Arguments
[A|B|C]
Returns:
<NRf> …
Example
FETC? A
FETCh? If set the parameter [A|B|C], the returned 19 floating point
measurements are <float>,...,<float> , in order are
(Uac,Iac,P,Upp,Upn,Ipp,Ipn,Freq,CF,PF,S,Q,Udc,Idc,Uthd,Ithd,Upeak,Urms,Irms)
MEASure? If set the parameter [A|B|C], the returned 17 floating point
measurements are <float>,...,<float>, in order are
(Uac,Iac,P,Upp,Upn,Ipp,Ipn,Freq,CF,PF,S,Q,Udc,Idc,Uthd,Ithd,Upeak)
FETCh[:SCALar]:POWer[:REAL]:TOTal?
MEASure[:SCALar]:POWer[:REAL]:TOTal?
This command is used to read the total power value.
Syntax:
FETCh[:SCALar]:POWer [:REAL]:TOTal?
MEASure[:SCALar]:POWer[:REAL]:TOTal?
Arguments
Returns:
<NRf>
Example
FETC:POW:TOT?