Loading...
SOURce Subsystem
Copyright © ITECH Electronic Co., Ltd. 64
Syntax:
CURRent[:LEVel][:IMMediate][:AMPLitude][:AC] <NRf+>[,NRf+][,NRf+]
Arguments
<NRf+>
MAXimum|MINimum
Query syntax:
CURRent[:LEVel][:IMMediate][:AMPLitude][:AC]? [MAXimum| MINimum]
Returns:
MAXimum|MINimum
Example
CURR 30
CURR 30,20,10
[SOURce:]CURRent[:LEVel][:IMMediate][:AMPLitude]:D
C <NRf+>,[NRf+],[NRf+]
DC current limit value setting command in Normal mode. This command is valid
only in DC and DC+AC modes.
Syntax:
CURRent[:LEVel][:IMMediate][:AMPLitude]:DC <NRf+>,[NRf+],[NRf+]
Query syntax:
CURRent[:LEVel][:IMMediate][:AMPLitude]:DC?
Returns:
<NRf+>
Example
CURRent:DC 30
[SOURce:]CURRent:SLEW[:AC] <NRf+>[,NRf+][,NRf+]
Sets the slope of load current. Unit A/ms.
Syntax:
CURRent:SLEW[:AC] <NRf+>[,NRf+][,NRf+]
Arguments
<NRf+>,[NRf+],[NRf+]