SOURce Subsystem
Copyright © ITECH Electronic Co., Ltd. 71
Arguments
<NRf+>[,NRf+][,NRf+]
Query syntax:
[SOURce:]CE:TB:R? [MAXimum| MINimum]
Arguments
<NRf+>
Example:
CE:TB:R 100
[SOURce:]CE:TB:RS <NRf+>[,NRf+][,NRf+]
This command is used to set or query the RS set under Rectifier single phase
RLC mode, Unit:Ω
Syntax:
[SOURce:]CE:TB:RS <NRf+>[,NRf+][,NRf+]
Query syntax:
[SOURce:]CE:TB:RS? [MAXimum| MINimum]
Example
CE:TB:RS 10
[SOURce:]CE:TB:L <NRf+>[,NRf+][,NRf+]
This command is used to set or query the L value under Rectifier single phase
RLC mode, Unit: mH
Syntax:
[SOURce:]CE:TB:L <NRf+>[,NRf+][,NRf+]
Query syntax:
[SOURce:]CE:TB:L? [MAXimum| MINimum]
Example
CE:TB:L 10
[SOURce:]CE:TB:C <NRf+>[,NRf+][,NRf+]
This command is used to set or query the C value under Rectifier single
phase RLC mode, Unit: uF
Syntax:
[SOURce:]CE:TB:C <NRf+>[,NRf+][,NRf+]