Message Remedy
The protective device ( Thermal relay ) ① Operate the clutch key and manu-
of the main motor is activated. ally reverse to mpve the knife to
the top.
② Remove the product.
③ Determine the cause and remove it.
④ Reset the activated protective
device.
⑤ Press 【 Alarm reset 】 on the touch
panel display.
Message Remedy
The protective device ( Thermal relay ) ① Reset the activated protective
of the blowermotor is activated. device.
② Press 【 Alarm reset 】 on the touch
panel display.
Message Remedy
T.D.C Activation ; the stopping ① Contact our servicedivision.
position of the knife has overshot the い。
fixed position.
Message Remedy
Clamp pressure drop is detected ① Operate the clutch key and manua-
during cutting operation. lly reverse to move the knife to the
③ Press the reset button ( Black ) at
the operation section of the main
④ If the alarm is causesd immediately
after replacement of hydraulic wo-
rking oil,bubbles remaining in the
hydraulic circuit are the cause.
Temporarily invalidate the error
detection function and repeat cla-
mping and knife operation until the
clamp motion becomes stable.
Then validate the error detection
function. For how to operate the
error detection function, contact
our service division. our service division.
⑤ If this alarm persists, inspection of the
hydraulic control is necessary. Contact
If this alarm is causes during knife operation, the cutting edge of the knife may be
stopped at e position lower than the bottom face of the clamp. A message and a
buzzer notify.
Do not reach beneath the knife.
This alarm insicates that clutch adjustment is necessary. The clutch lining becomes
worn as the machine keeps operating.
Periodic inspection and adjustment are necessary.
Do not reach beneath the knife.
If this alarm is caused during knife operation,
the cuttingedge of the knife may be stopped
at a position lower than the botton face of
the clamp.
Injuries will be caused.