17.3.4.2 Setting own ship's parameters
Set the following items in the [Ship's Parameters] dialog.
Setting Item Description of Setting Setting Value
Ship's Name Enter own ship's name in the box. Max. 20 characters
Length (of ship) Enter own ship's length in the box. 1.0 to 1022.0 m
Beam (ship's width) Enter own ship's beam in the box. 1.0 to 126.0 m
Height from keel to MAX point Enter the height of the ship from the keel to the
maximum point in the box.
1.0 to 126.0 m
Keel-Trans
(distance between the transducer
and the keel)
Enter the distance between the transducer of the
depth sounder and the keel. (Required when
displaying the water depth with the keel fixed)
0.0 to 20.0 m
MAX Course Change
(limit value of course change
angle)
Enter the limit value of the course change angle
of the planned route in the box.
20.0 to 359.9°
MAX Speed Limit Enter the ship's maximum speed in the box. 10.0 to 99.9 kn
MIN Speed Limit Enter the ship's minimum speed in the box. 0.0 to 89.9 kn
MAX ROT Enter the maximum rate of turn in the box. 1.0 to 1200.0°/min
MIN ROT Enter the minimum rate of turn in the box. 0.0 to 570.0°/min
MIN Turn Radius Enter the minimum turn radius in the box. 0.00 to 9.99 NM
Synchronizing setting
The [Ship's Parameters] dialog enables common setting items and individual setting items for RADAR,
ECDIS, and Conning (called a task station individually). Once common items are set in any of the task
stations, RADAR, ECDIS, and Conning, the settings are reflected (synchronized) in other task stations.
By setting common items in the state where all the task stations are active, the common setting items
are synchronized in all the task stations.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the JRC ECDIS and is the answer not in the manual?

JRC ECDIS Specifications

General IconGeneral
Display TypeLCD
Radar OverlayYes
AIS IntegrationYes
Operating Temperature-15°C to +55°C
Chart FormatS-57, S-63
Power Supply24V DC
InterfacesEthernet, USB
ComplianceIMO

Related product manuals