Ensure that you have the following parts and tools available:
DC power source cables (14 AWG) with ring lug (Molex 0190700067 or equivalent)
(not provided) attached to them by a licensed electrician
Phillips (+) screwdriver, number 2
To connect DC power to the switch:
1. Ensure that the input circuit breaker is open so that the cable leads will not become
active while you are connecting DC power.
NOTE: The DC power supply in the switch has four terminals labeled A+,
B+, A–, and B– for connecting DC power source cables labeled
positive (+) and negative (–). The terminals are covered by a clear plastic
cover.
NOTE: The A+ and B+ terminals are referred to as +RTN and A– and B–
terminals are referredto as–48 V in “DC Power WiringSequenceWarning”
on page 188 and “DC Power Electrical Safety Guidelines” on page 183.
2. Grasp the plastic cover in the middle, gently flex it outwards, and pull it out. Save the
cover.
3. Remove the screws on the terminals using the screwdriver. Save the screws.
WARNING: Ensure that the power cables do not block access to switch
components or drape where people can trip on them.
4. Connect the power supply to the power sources. Secure power source cables to the
power supply by screwing the ring lugs attached to the cables to the appropriate
terminals by using the screw from the terminals (see Figure 37 on page 108).
Figure 37: Securing Ring Lugs to the Terminals on the DC Power Supply
g021215
A-
DC power source cable
with lug attached
B-
B+
A+
DC power terminals:
Copyright © 2015, Juniper Networks, Inc.108
Complete Hardware Guide for EX3300 Ethernet Switches

Table of Contents

Other manuals for Juniper EX3300

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper EX3300 and is the answer not in the manual?

Juniper EX3300 Specifications

General IconGeneral
Ethernet LANYes
Authentication methodRADIUS, TACACS+
Connectivity technologyWired
Ethernet interface typeGigabit Ethernet
Number of VLANs4096
Networking standardsIEEE 802.1ab, IEEE 802.1D, IEEE 802.1Q, IEEE 802.1s, IEEE 802.1w, IEEE 802.1x, IEEE 802.3, IEEE 802.3ab, IEEE 802.3ad, IEEE 802.3x, IEEE 802.3z
Ethernet LAN data rates10, 100, 1000 Mbit/s
Copper ethernet cabling technology1000BASE-T, 100BASE-TX, 10BASE-T
Console port-
ExpressCard slotNo
Fiber ports quantity4
USB 2.0 ports quantity0
Basic switching RJ-45 Ethernet ports quantity48
Throughput130 Mpps
Number of queues8
MAC address table16000 entries
Maximum data transfer rate176 Gbit/s
Supported data transfer rates10, 100, 1000Mbps
Switch typeManaged
Switch layerL2
Security algorithmsSSH-2
Power sourceAC
AC input voltage100 - 240 V
Power consumption (typical)100 W
Form factor1U
Product colorBlack
Flash memory1024 MB
Processor frequency1000 MHz
Compatible operating systemsJunos
Operating altitude0 - 3049 m
Non-operating altitude0 - 4877 m
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)0 - 45 °C
Storage relative humidity (H-H)0 - 95 %
Operating relative humidity (H-H)10 - 85 %
Supported network protocolsIPv6
Weight and Dimensions IconWeight and Dimensions
Depth310 mm
Width437 mm
Height44 mm
Weight4900 g