4. Connect each power supply to the power sources. Insert the coupler end of the power cord into the
AC power cord inlet on the AC power supply faceplate.
5. Push the power cord retainer onto the power cord (see Figure 28 on page 80).
Figure 28: Connecng an AC Power Cord to an AC Power Supply in an EX4600 Switch
1— Power cord retainer
6. If the AC power source outlet has a power switch, set it to the OFF (O) posion.
NOTE: The switch powers on as soon as power is provided to the power supply. There is no
power switch on the device.
7. Insert the power cord plug into an AC power source outlet.
8. If the AC power source outlet has a power switch, set it to the ON (|) posion.
9. Verify that the AC and DC LEDs on each power supply are lit green.
If the amber fault LED is lit, remove power from the power supply, and replace the power supply
(see"Removing a Power Supply from an EX4600 Switch" on page 98 ). Do not remove the power
supply unl you have a replacement power supply ready: the power supplies or a blank cover panel
must be installed in the switch to ensure proper airow.
CAUTION: Replace a failed power supply with a blank panel or new power supply
within 1 minute of removal to prevent chassis overheang.