USB Port Specicaons the PTX10001-36MR | 73
Cable Specicaons for Console and Management Connecons for the
PTX10001-36MR
Table 32 on page 71 lists the specicaons for the cables that connect the PTX10001-36MR to a
management device.
NOTE: All RJ-45 connectors must conform to the rules and regulaons as described in the FCC
specicaon 47 CFR Part 68.
Table 32: Cable Specicaons for Console and Management Connecons for the PTX10001-36MR
Port on
PTX10001-36MR
Cable Specicaon Cable Supplied Maximum Length Device
Receptacle
Console (CON/ToD)
port
RS-232 (EIA-232)
serial cable
One 7-foot (2.13-
meter)-long RJ-45
patch cable and RJ-45
to DB-9 adapter
7 feet
(2.13 meters)
RJ-45
Management (MGMT)
port
Category 5 cable or
equivalent suitable for
1000BASE-T
operaon
One 7-foot (2.13-
meter)-long RJ-45
patch cable
328 feet
(100 meters)
RJ-45
Management Port Connector Pinouts for the PTX10001-36MR
The 10/100/1000BASE-T RJ-45 management port (labeled MGMT) uses an RJ-45 connector to connect
to a management device for out-of-band management.