8. Place the power supply in the anstac bag or on the anstac mat placed on a at, stable surface.
9. Install a new power supply within two minutes of removing the old one.
Install the DC Power Supply in the PTX10001-36MR
CAUTION: Install the power supply within two minutes of removal to prevent chassis
overheang. Before removing the power supply, ensure you have a replacement power
supply available.
1. Wrap and fasten one end of the ESD wrist strap around your bare wrist, and connect the other end
of the strap to the ESD point on the device.
2. If the power supply has protecve plasc wrap, peel and remove the plasc wrap from all four sides
of the power supply.
3. Taking care not to touch power supply components, pins, leads, or solder connecons, remove the
power supply from its bag.
4. To prevent damage to the equipment caused by stac discharge, aach an ESD grounding strap to
your bare wrist, and connect the strap to one of the ESD points on the chassis.
5. Taking care not to touch power supply components, pins, leads, or solder connecons, remove the
power supply from its bag.
6. Using both hands, place the power supply in the power supply slot on the eld replaceable units
(FRU) panel of the PTX10001-36MR and slide it in unl it is fully seated and the locking lever slides
into place. See Figure 46 on page 113.
Figure 46: Install a DC Power Supply
113