• JTAC—If you need assistance during troubleshoong, you can contact the Juniper Networks
Technical Assistance Center (JTAC) by using the Web or by telephone. If you encounter soware
problems, or problems with hardware components not discussed here, contact JTAC.
PTX10001-36MR Alarm Messages Overview
When the Roung Engine detects an alarm condion, it lights the red or yellow alarm LED on the
management panel as appropriate. To view a more detailed descripon of the alarm cause, issue the
show system alarm CLI command:
user@host> show system alarm
1 alarm currently active
Alarm time Class Description
2020-07-01 01:18:35 PDT Major chassis No Redundant Power
System Alarm Messages on the PTX10001-36MR
System alarms indicate a failure on the device or one of its components. System alarms are preset and
cannot be modied.
System alarms on PTX10001-36MR devices have two severity levels:
• Major (red)—Indicates a crical situaon on the device that has resulted from one of the condions
described in Table 35 on page 129. A red alarm condion requires immediate acon.
• Minor (yellow or amber)—Indicates a noncrical condion on the device that, if le unchecked, might
cause an interrupon in service or degradaon in performance. A yellow alarm condion requires
monitoring or maintenance.
Table 35 on page 129 describes the system alarm messages on the PTX10001-36MR.
Table 35: PTX10001-36MR System Alarm Messages
Component Alarm Type CLI Message Recommended Acon
Fans Major (red)
Fan Failure
Replace the fan module and report
the failure to customer support.
129