JTAC—If you need assistance during troubleshoong, you can contact the Juniper Networks
Technical Assistance Center (JTAC) by using the Web or by telephone. If you encounter soware
problems, or problems with hardware components not discussed here, contact JTAC.
PTX10001-36MR Alarm Messages Overview
When the Roung Engine detects an alarm condion, it lights the red or yellow alarm LED on the
management panel as appropriate. To view a more detailed descripon of the alarm cause, issue the
show system alarm CLI command:
user@host> show system alarm
1 alarm currently active
Alarm time Class Description
2020-07-01 01:18:35 PDT Major chassis No Redundant Power
System Alarm Messages on the PTX10001-36MR
System alarms indicate a failure on the device or one of its components. System alarms are preset and
cannot be modied.
System alarms on PTX10001-36MR devices have two severity levels:
Major (red)—Indicates a crical situaon on the device that has resulted from one of the condions
described in Table 35 on page 129. A red alarm condion requires immediate acon.
Minor (yellow or amber)—Indicates a noncrical condion on the device that, if le unchecked, might
cause an interrupon in service or degradaon in performance. A yellow alarm condion requires
monitoring or maintenance.
Table 35 on page 129 describes the system alarm messages on the PTX10001-36MR.
Table 35: PTX10001-36MR System Alarm Messages
Component Alarm Type CLI Message Recommended Acon
Fans Major (red)
Fan Failure
Replace the fan module and report
the failure to customer support.
129