Table 35: PTX10001-36MR System Alarm Messages
(Connued)
Component Alarm Type CLI Message Recommended Acon
Fan I2C Failure
Check the system log for one of the
following messages and report the
error message to customer support:
CM ENV Monitor: Get fan speed
failed.
fan-number
is NOT spinning @
correct speed, where
fan-number
can be 0, 1, 2, 3, 4, or 5.
Fan
fan-number
Not Spinning
Remove and check the fan module
for obstrucons, and then reinsert
the fan module. If the problem
persists, replace the fan module.
Minor (yellow)
Fan/Blower Absent
Check the system log for the
message
fan-number
Absent, where
fan-number
can be 0, 1, 2, 3, 4, or 5.
Install the fan module.
Power supplies Major (red)
PEM
pem-number
Airflow not matching
Chassis Airflow
Replace the power supply with a
power supply that supports the
same airow direcon as the
chassis.
PEM
pem-number
I2C Failure
Check the system log for one of the
following messages and report the
error message to customer support:
I2C Read failed for device
number
, where
number
can be from
123 throgh 125.
PS
number
: Transitioning from
online to offline, where power
supply (PS)
number
can be 0 or 1.