LL17 Safety Release
The Safety Release function turns off the acceleration jerk rates and raises the maximum
torque limit to 300% of LM07 Motor Torque for one run to drive an elevator car off the
safeties.
Motor
Type
Setting Options
NUM
Range
Units
Default
Pass
Level
Ind.
PM
Min.
Max.
Imp.
Met.
RW
RW
Tune Activation
-
0
2
-
-
0
Basic
OFF
0
-
-
-
-
-
-
Cancel
1
Start
2
Tune State
-
0
USER: Acceleration and start jerk
increased. Run elevator at High
Speed or Inspection Speed.
16
STATUS: Running elevator
32
SUCCESS: Safety release
complete
160
Cannot start tune because another
tune mode is already active
176