USER: Run empty car UP on Inspection
Speed
STATUS: Determining encoder pole offset
FAILURE: Speeds not correct, verify encoder
PPR/Signal/Mounting
STATUS: Motor phasing incorrect, swapping
encoder phases, run the car UP again
USER: Did the elevator travel UP?
STATUS: Reversing motor direction, run the
car UP again
FAILURE: Encoder error detected, verify
encoder PPR/Signal/Mounting
FAILURE: Minimum measurement speed not
reached, increase speed, run the car UP again
SUCCESS: SPI complete, do Encoder
Synchronization next
Cannot start tune because another tune mode
is already active
ERROR: Tune Motor with LL01 first
Encoder Pole Position Learn
USER: Run empty car UP on Inspection
Speed
STATUS: Determining encoder pole offset
FAILURE: Speeds not correct, verify encoder
PPR/Signal/Mounting
STATUS: Motor current too large, swapping
encoder phases, run the car UP again
USER: Did the elevator travel UP?
STATUS: Reversing motor direction, run the
car UP again
FAILURE: Encoder error detected, verify
encoder PPR/Signal/Mounting
FAILURE: Minimum measurement speed not
reached, increase speed, run the car UP again
SUCCESS: Encoder Pole Learn complete
Cannot start tune because another tune mode
is already active
ERROR: Tune Motor with LL01 first