Keyscan Inc. A Member of the Kaba Group – CA150 Rev. B Installation Guide (07.15)
Switch Settings
S2.1 – S2.6
FC output from the
reading device.
Standard 26-bit & Keyscan
36-bit
Standard –
except for 26-bit
cards Facility
Code = 0
Enter 0 (zero) for the
facility code in the Client
software to ignore the
FC output from the
reading device.
Northern 34-bit & Keyscan
36-bit
Standard –
except for 34-bit
cards Facility
Code = 0
Enter 0 (zero) for the
facility code in the Client
software to ignore the
FC output from the
reading device.
Corby 30-bit & Keyscan
36-bit
Standard -
except for 30-bit
cards Facility
Code = 0
Enter 0 (zero) for the
facility code in the Client
software to ignore the
FC output from the
reading device.
Legacy GE 40-bit or Casi-
Rusco Ex. Prox-Lite 941-W
RDR
Legacy 37-bit (37 Bit Corp
H10302) & Keyscan 36-bit
Legacy Keyscan England
36-bit with no
manufacturer's code check
Format does not support
Keyscan WSSKP-1
Keypad with PIN use.
Legacy HID 35-bit &
Keyscan 36-bit
Standard –
except for HID
35-bit cards -
Company ID
Code ignored.
See Reader Format –
Ref # C – preferred
option.
HID Computrol 34-bit &
Keyscan 36-bit
Legacy 37-bit (alternate 37
Bit Corp H10304) &
Standard 26-bit & Keyscan
36-bit
Legacy Chubb 36-bit &
Keyscan 36-bit
No parity check on
Chubb card.
Honeywell 40-bit &
Keyscan 36-bit
Format does not support
Keyscan WSSKP-1
Keypad with PIN use.
ITI 29-bit & 26-bit &
Keyscan 36-bit
Legacy 37-bit (37 Bit Corp
H10302) & Standard 26-bit
& Keyscan 36-bit