AKD2G-S Installation, Safety 1 | 8 Electrical Installation
8.8 External Regen resistor (X3)
For technical data on the rheostatic brake circuit ( # 42).
Fusing (such as fusible cut-outs or power switches) to be provided by the user.
8 pin, pitch 7.62 mm
optional T version
Mating connector data see ( # 51).
Pin Signal Description
5 RBint internal Regen resistor
6 -RB external Regen resistor -
7 +DC (+RBext) external Regen resistor +
8.8.1 Fusing and Wiring
FB1 / FB2 fusing
Drive Model Ampere
rating@240V
Ampere
rating@480V
UL region
example:
CE Region
example: Siba
all AKD2G-Sxx 10A 40A Bussmann
FWP-xxA14F
110V to 400V: gRL(gS)
400V to 480V: aR
FPS: Frizlen DC Power Switch
RBext FPS Range [In] cable cross section
BAR(U)1500-33 FPS-16 10 to 16 A min. 2.5 mm²