8.10.3 Master-Slave control
Several AKD2G can be connected as slave drives to another AKD2G which acts as a mas-
ter. The slave drives use the master's encoder output signal (EEO, ( # 91)) as command
input and follow these commands (velocity and direction).
8.10.3.1 Master-Slave using X22
The master is configured for EEO4 ( # 91) on X2, the Slave uses X1 for command input.
8.10.3.2 Master-Slave using optional X23 or X41
The master is configured for EEO1 ( # 92) on X23 or EEO3/EEO4 (( # 92) with SFA) on
X41, the Slave uses X23 (or X41 with SFA) for command input.
AKD2G-S Installation, Safety 1 | 8 Electrical Installation