9.1.6 Expansion card -SYNQNET-
This section describes the SynqNet expansion card for S700. Information on the range of
functions and the software protocol can be found in the SynqNet documentation.
9.1.6.1 NODE ID Switch
With these hexadecimal switches you can set the main and low significant bytes of the
Node ID separately. SynqNet does not require an address for correct operation in the net-
work, however in some machines this can be a convenient way of identifying build options
to the application program.
9.1.6.2 Node LED table
LED# Name Function
LED1, green
LINK_IN
ON = receive valid (IN port)
OFF= not valid, power off, or reset.
LED2, yellow
CYCLIC
ON = network cyclic
BLINK = network not cyclic
OFF = power off, or reset
LED3, green
LINK_OUT
ON = receive valid (OUT port)
OFF = not valid, power off, or reset
LED4, yellow
REPEATER
ON = repeater on, network cyclic
BLINK = repeater on, network not cyclic
OFF = repeater off, power off, or reset
9.1.6.3 SynqNet Connection, Connector X21B/X21C (RJ-45)
Connection to the SynqNet network via RJ-45 connectors (IN and OUT ports) with inte-
grated LEDs.
S701x2-S724x2 Instructions Manual 135
Kollmorgen 07/2014 Expansions
LED2 LED1 LED4 LED3