DISK
1.1
131
25) Load .WAV: selected icon
The selected WAVE le will be loaded as a sample.
1 To load the data, press the [F8] (OK) key. To cancel
without loading, press the [F7] (Cancel) key.
The sample will be loaded following the last-numbered
sample that currently exists in memory by having been
sampled or loaded (Append load).
Files with an extension of other than .AIF/.WAV cannot
be recognized as AIFF/WAVE les. In this case, use the
Utility Rename (1.13a) to change the last four char-
acters of the lename to .AIF/.WAV
If the data that is loaded as a sample contains a loop
point, you can set S.Ofs(Start Offset) (PROG 2.12b/
3b) on the TRITON-Rack so that the sound will begin
from the loop point.
If data whose sample size is 8 bits or less is loaded, it
will be converted into 16 bit data inside the TRITON-
Rack. This will mean that the amount of internal mem-
ory consumed will be approximately twice as large as
the le size. The increase in size resulting from this con-
version may mean that it is impossible to save that data
on a oppy disk.
Loading AKAI S1000/S3000 format Sample les and
Program les
The TRITON-Rack can load AKAI S1000/S3000 format Sam-
ple les and Program les. The loaded Sample or Program
le data can be used as a sample or multisample respec-
tively. When the loaded data is then saved to storage media,
it will be saved as a Korg format .KSF le or .KMP le
respectively.
AKAI S1000/S3000 format stereo Sample les and Program
les whose names end in -L and -R can be loaded into
the TRITON-Rack as stereo samples and multisamples.
When the above les are loaded, -L and -R will auto-
matically be moved to the end of the sample name or multi-
sample name (15th and 16th character) so that they can
automatically be recognized as stereo samples or multisam-
ples.
26) Load AKAI Sample File: selected icon
The selected Sample will be loaded as a sample.
1 To load the data, press the [F8] (OK) key. To cancel
without loading, press the [F7] (Cancel) key.
The sample will be loaded following the last multisample
or sample that currently exists in the TRITON-Racks
memory by having been sampled or loaded (Append
load). If the loaded data is then saved to storage media, it
will be saved as a Korg format .KSF le. (possible to
export as a .AIF, .WAV format
p.135 Export Smpl AIF/
WAV)
If the data that is loaded as a sample contains a loop
point, you can set S.Ofs(Start Offset) (PROG 2.12/
3b) on the TRITON-Rack so that the sound will begin
from the loop point.
If the end (11th and 12th characters) of the sample name
is -L and -R, the -L and -R will automatically
be moved to the end of the TRITON-Racks sample
name (15th and 16th characters).
When you load two les whose sample names are iden-
tical except for ending in -L and -R, and assign
them to a stereo multisample in Sampling mode, they
will be recognized as a stereo sample.
Sample les
27) Load AKAI Program File: selected icon
The selected Program le will be loaded as a multisample.
When the loaded data is saved to storage media, a Program
le will be saved as a .KMP le, and a Sample le will be
saved as a .KSF le.
1 To load the data, press the [F8] (OK) key. To cancel
without loading, press the [F7] (Cancel) key.
Samples will be loaded starting at the rst unoccupied
number following the last multisample or sample that
currently exists in TROTON-Racks memory by having
been sampled or loaded. Only valid Program les or
Samples les will be loaded (Append load).
If the Sample les used by the Program le are not in the
current directory or below it, a dialog box will appear,
allowing you to specify the directory. Use the procedure
If the le to load cannot be found,…” (
p.125) to load
the required Sample les.
Since PCM memory overow checking is performed
when loading each sample le, an overow may occur
during the loading process.
If a loaded multisample is assigned samples whose
sample names end in -L and -R, an -L and -R
will automatically be added to the end (15th and 16th
characters) of the multisample name.
When you load two multisamples whose multisample
names are identical except for ending in -L and -R,
they will be recognized in Sampling mode as a stereo
multisample.
Parameter AKAI S1000/S3000
format
TRITON-Rack format
after loading
Loop points Multiple settings possible Of the multiple loop points,
the settings for the rst
HOLD loop are used.
If there is no HOLD loop,
use the longest loop
Loop length Settable with resolution
of less than one sample
Resolution of less than one
sample is ignored