U100 Setting:[High Altitude]
1. Select an item to be set.
Initial setting: Mode0
* : MCH compensation is set to "3" when it sets to the high ground 1 ,high ground 2 or the
high ground 3.
* : Plain weight attribute information is set to "Normal 1" when it sets to the high ground 1
,high ground 2 or the high ground 3.
2. Press the start key. The value is set.
Setting:[MCH]
1. Change the setting value using the +/- keys or numeric keys.
* : A setup is possible only when set to the "standard" by high-ground setup.
2. Press the start key. The value is set.
Setting:[Protect table]
1. Select an item to be set.
Initial setting: Mode0
2. Press the start key. The value is set.
Setting:[Drum Aging]
1. Select an item to be set.
Initial setting: Off
2. Press the start key. The value is set.
Completion
Press the stop key when main charger output stops. The screen for selecting a maintenance item
No. is displayed.
Item No. Description
Display Description
Mode0 Standard (Factory setting)
Mode1 High ground 1 (1500 to 2500 m)
Mode2 High ground 2 (2500 m or more)
Mode3 High ground 3 (3500 m or more)
Display Description
Setting
range
Initial
setting
Value MCH compensation 1 to 5 3
Display Description
Mode0 It changes by drum drive time.
Mode1 Initial fixation
Display Description
On with aging (it operates by lapsed time)
Off with not aging