2MV
1-4-6
4301 Duplex sensor non arrival
jam
The duplex sensor (DUS) does not turn on during
paper feed from cassette 1.
F
4302 The duplex sensor (DUS) does not turn on during
paper feed from cassette 2.
F
4303 The duplex sensor (DUS) does not turn on during
paper feed from cassette 3.
F
4304 The duplex sensor (DUS) does not turn on during
paper feed from cassette 4.
F
4309 The duplex sensor (DUS) does not turn on during
paper feed from the MP tray.
F
4311 Duplex sensor stay jam The duplex sensor (DUS) does not turn off during
paper feed from cassette 1.
F
4312 The duplex sensor (DUS) does not turn off during
paper feed from cassette 2.
F
4313 The duplex sensor (DUS) does not turn off during
paper feed from cassette 3.
F
4314 The duplex sensor (DUS) does not turn off during
paper feed from cassette 4.
F
4319 The duplex sensor (DUS) does not turn off during
paper feed from the MP tray.
F
4901 Bridge conveying sensor 1
non arrival jam
The bridge conveying sensor 1 (BRCS1) does not
turn on during paper feed from cassette 1.
I
4902 The bridge conveying sensor 1 (BRCS1) does not
turn on during paper feed from cassette 2.
I
4903 The bridge conveying sensor 1 (BRCS1) does not
turn on during paper feed from cassette 3.
I
4904 The bridge conveying sensor 1 (BRCS1) does not
turn on during paper feed from cassette 4.
I
4908 The bridge conveying sensor 1 (BRCS1) does not
turn on during paper feed from duplex section.
I
4909 The bridge conveying sensor 1 (BRCS1) does not
turn on during paper feed from the MP tray.
I
Code Contents Conditions
Jam
location*