Severity
Error
UserResponse
Completethefollowingsteps:
1.YoumustAC-cyclethesystemtore-enableaffectedDIMMconnectororre-enablemanually
usingF1setup
2.Ifthenodehasbeenrecentlyinstalled,serviced,moved,orupgraded,checktoensurethat
DIMMsarefirmlyseatedandthatnoforeignmaterialcanbeseenintheDIMMconnector.If
eitherconditionisobserved,correctandretrywiththesameDIMM.(Note:EventLogmay
containarecent00580A4eventdenotingdetectedchangeinDIMMpopulationthatcould
berelatedtothisproblem.)
3.Ifproblempersists,replacetheDIMMidentifiedbyLightPathand/oreventlogentry.
4.Ifproblemre-occursonthesameDIMMconnector,swaptheotherDIMMsonthesamememory
channelacrosschannelsoneatatimetoadifferentmemorychannelorProcessor.(check
serviceinformationforthisproduct/Installguideforpopulationrequirementsforsparing/paring
modes).IfproblemfollowsamovedDIMMtoadifferentmemorychannel,replacethatDIMM.
5.CheckIBMsupportsiteforanapplicableservicebulletinorfirmwareupdatethatappliestothis
memoryerror.
6.(Trainedservicetechnicianonly)IfproblemstayswiththeoriginalDIMMconnector,re-inspect
DIMMconnectorforforeignmaterialandremove,iffound.Ifconnectorisdamaged,replace
systemboard.
7.(Trainedservicetechnicianonly)RemoveaffectedProcessorandinspectProcessorsocketpins
fordamagedormis-alignedpins.Ifdamageisfound,orthisisanupgradeProcessor,replace
systemboard.IftherearemultipleProcessor’s,swapProcessor’stomoveaffectedProcesorto
anotherProcessorsocketandretry.IfproblemfollowstheaffectedProcessor(orthereisonly
oneProcessor),replacetheaffectedProcessor.
8.(TrainedServicetechnicianonly)Replacethesystemboard.
S.68005[S.68005]AnerrorhasbeendetectedbythetheIIOcorelogiconBus%.TheGlobalFatal
ErrorStatusregistercontains%.TheGlobalNon-FatalErrorStatusregistercontains%.Please
checkerrorlogsforthepresenceofadditionaldownstreamdeviceerrordata.
Explanation:CriticalIOH-PCIError
Severity
Error
UserResponse
Completethefollowingsteps:
1.ChecklogforaseparateerrorforanassociatedPCIedeviceandservicethaterror.
2.CheckIBMsupportsiteforanapplicableservicebulletinorfirmwareupdateforthesystemor
adapterthatappliestothiserror.
3.(TrainedServicetechnicianonly)Replacethesystemboard.
W.11004[W.11004]AprocessorwithinthesystemhasfailedtheBIST.
Explanation:ProcessorSelfTestFailureDetected
Severity
418LenovoSystemx3250M4InstallationandServiceGuide