Function library
Function blocks
9.2.39 Limiter (LIM)
9-135
L
EDSVS9332S-D11 EN 3.0
9.2.39 Limiter (LIM)
Purpose
This FB is used to limit signals to adjustable ranges of values.
LIM1
LIM1-OUT
LIM1-IN
C0633
C0630
C0631
C0632
Fig. 9-96 Limiter (LIM1)
Signal
Source Note
Name Type DIS DIS format CFG List Lenze
LIM1-IN1 a C0633 dec [%] C0632 1 1000 -
LIM1-OUT a - - - - - -
Function
z If the input signal exceeds the upper limit (C0630), the upper limit is effective.
z If the input signal falls below the lower limit (C0631), the lower limit is effective.
Tip!
The lower limit (C0631) must be smaller than the upper limit (C0630).