During operation
Status indications
6-1
L
EDSVS9332S-C EN 3.0
6 During operation
6.1 Status indications
6.1.1 Display on the controller
Two LEDs at the front of the controller indicate the controller status.
LED green LED red Cause Check
Controller enabled; no fault
Controller inhibit, switch-on inhibit C0183; or C0168/1
Fail C0168/1
Warning, fail-QSP C0168/1
:on :off : blinking
6.1.2 Display on the keypad
Status indications in the display indicate the controller status.
Display Controller status Check
RDY Controller ready for operation, controller can be inhibited C0183, C0168/1
IMP Pulses at the power stage inhibited C0183, C0168/1
I
max
Max. current reached
M
max
Max. torque reached
Fail Fault through TRIP, message, fail-QSP or warning C0183, C0168/1