EasyManua.ls Logo

Lenze EVS 9300 series - Freely Assignable Digital Outputs; Freely Assignable Analog Inputs

Lenze EVS 9300 series
504 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Configuration
Change of the terminal assignment
8.4.2 Freely assignable digital outputs
8-37
L
EDSVS9332S-D11 EN 3.0
8.4.2 Freely assignable digital outputs
Four freely assignable digital outputs are available (X5/A1 X5/A4). You can define a polarity for
each input which serves to determine the input to be HIGH active or LOW active.
The most important codes can be found in the submenu: DIGOUT (digital outputs).
Change assignment:
1. Select the output which is to be assigned to another function via the subcode under C0117.
2. Change to the parameter level with PRG. Select the signal from the indicated list, which is to
be output via the selected output terminal. Change to the code level with PRG.
3. Determine the polarity (HIGH active or LOW active) via the subcode of the output under
C0118.
4. Repeat step 1. to 3., until all outputs desired are assigned.
8.4.3 Freely assignable analog inputs
The most important codes can be found in the submenu: AIN1 X6.1/2 or AIN2 X6.3/4 (analog input 1
(X6.1/2) or analog input 2 (X6.3/4))
Change assignment:
1. Selecttheinputofthefunctionblocktobeassignedtoanewsourceinthecodelevel.
–Example
Determine the source for the input Main setpoint (NSET-N) in the function block Speed
setpoint conditioning” (NSET) under C0780.
2. Change to the parameter level with PRG. Select the signal from the indicated list, which is to
be used for the selected input.
3. Repeat steps 1. and 2. until all inputs required are assigned.
4. Remove unwanted links (see Chapter 9.1.3).

Table of Contents