EasyManua.ls Logo

Lenze EVS 9300 series - Actual Value Display Via Codes

Lenze EVS 9300 series
504 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
During operation
Status indications
6-3
l
EDSVS9332S-C EN 3.0
6.1.4 Actual value display via codes
You can read different actual values using the following codes:
Code Meaning
C0051 Absolute actual speed [rpm]
C0052 Absolute motor voltage [V]
C0053 Absolute DC bus voltage [V]
C0054 Absolute motor current [A]
C0060 Rotor position [Inc/rev]
C0061 Heatsink temperature [°C]
C0063 Absolute motor temperature [°C]
Display only if the KTY (PTC) is connected via X7 or X8.
C0064 Controller load [%]
Identification
z You can read the software version of the controller under C0099.
z C0093 indicates the controller type.