Glossary
abc
14-1
L
EDSVS9332S-M EN 3.0
Part M
14 Glossary
Term Meaning
AIF Automation interface (X1)
CAN Controller Area Network
CE Communauté Européenne (English: European Community)
Code For entry and display (access) of parameter values.
Variable addressing according to the format ”code/subcode” (Cxxxx/xx).
All variables can be addressed via the code digits.
Contouring error Deviation between momentary p osition setpoint and actual position. Display for a momentary contouring error under C0908.
Contouring error monitoring Monitors the momentary contouring error if the contouring error tolerance is exceeded and releases a fault indication, if necessary.
Contouring error tolerance If the contouring error reaches a defined contouring error tolerance, a fault indication is released.
Ctrl. enable Controller enable
Ctrl. inhibit Controller inhibit ( = Controller enable )
FB Function block
Fieldbus For data exchange between master control and controller (e.g. INTERBUS or PROFIBUS).
FPDA Freely programmable digital output
FPDE Freely programmable digital input
GDC Global Drive Control (PC program for Lenze controllers - Windows)
INTERBUS Industrial communication standard to DIN E19258
JOG JOG speed or input for J OG speed
KTY “Linear” temperature sensor in the motor winding
LECOM Lenze Communication
LEMOC2 PC program for Lenze controllers - DOS
LU Undervoltage
Master A master is for instance a PLC or PC.
OU Overvoltage
PC Personal Computer
PLC Programmable logic controller
PM Permanent magnet
Process data For instance, setpoints and actual value which are to be exchanged as quickly as possible. Usually, this applies to smaller data
amounts which are transmitted cyclically.
With PORFIBUS these data are transmitted via the logic process data channel.
PROFIBUS Communication standard DIN 19245, consisting of three parts
PTC PTC thermistor with defined tripping temperature
QSP Quick stop
RFG Ramp function generator
Slave Bus participant that must wait for the master’s request to send data. Controllers are slaves.
SSC Sensorless speed control
SSI Synchronous serial interface
Target position The target which is to be approached by means of a defined traversing profile.
TKO Thermal contact / normally closed contact