Technical data
3.3 Rated data
3-4
L
EDSVS9332S-B EN 3.0
3.3 Rated data
3.3.1 Types 9321 to 9325
Type EVS9321-ES EVS9322-ES EVS9323-ES EVS9324-ES EVS9325-ES
Order No. EVS9321-ES EVS9322-ES EVS9323-ES EVS9324-ES EVS9325-ES
Type EVS9321-CS EVS9322-CS EVS9323-CS EVS9324-CS EVS9325-CS
Order No. EVS9321-CS EVS9322-CS EVS9323-CS EVS9324-CS EVS9325-CS
Mains voltage U
r
[V] 320 V - 0 % U
r
528 V + 0 % ; 45 Hz - 0 % ... 65 Hz + 0 %
Alternative DC supply U
G
[V] 460 V - 0 % U
G
740 V + 0 %
Mains current with mains filter I
r
[A] 1.5
2.1
2.5
3.5
3.9
5.5
7.0
-
12.0
16.8
Data for the operation on a mains: 3 AC/400 V / 50 Hz/60 Hz
Motor power (4-pole ASM)
P
r
[kW] 0.37 0.75 1.5 3.0 5.5
M
o
t
o
r
p
o
w
e
r
(
4
p
o
l
e
A
S
M
)
P
r
[hp] 0.5 1.0 2.0 4.0 7.5
Output power U, V, W (8 kHz*) S
r8
[kVA] 1.0 1.7 2.7 4.8 9.0
Output power +U
G
,-U
G
2)
P
DC
[kW] 2.0 0.75 2.2 0.75 0
Output current (8 kHz*) I
r8
[A] 1.5 2.5 3.9 7.0 13.0
Output current (16 kHz*) I
r16
[A] 1.1 1.8 2.9 5.2 9.7
Max. output current (8 kHz*)
1)
I
max8
[A] 2.3 3.8 5.9 10.5 19.5
Max. output current (16 kHz*)
1)
I
max16
[A] 1.7 2.7 4.4 7.8 14.6
Max. standstill current (8 kHz*) I
08
[A] 2.3 3.8 5.9 10.5 19.5
Max. standstill current (16 kHz*) I
016
[A] 1.7 2.7 4.4 7.8 14.6
Data for the operation on a mains: 3 AC/480 V / 50 Hz/60 Hz
Motor power (4-pole ASM)
P
r
[kW] 0.37 0.75 1.5 3.0 5.5
M
o
t
o
r
p
o
w
e
r
(
4
p
o
l
e
A
S
M
)
P
r
[hp] 0.5 1.0 2.0 4.0 7.5
Output power U, V, W (8 kHz*) S
r8
[kVA] 1.2 2.1 3.2 5.8 10.8
Output power +U
G
,-U
G
2)
P
DC
[kW] 2.0 0.75 2.2 0.75 0
Output current (8 kHz*) I
r8
[A] 1.5 2.5 3.9 7.0 13.0
Output current (16 kHz*) I
r16
[A] 1.1 1.8 2.9 5.2 9.7
Max. output current (8 kHz*)
1)
I
max8
[A] 2.3 3.8 5.9 10.5 19.5
Max. output current (16 kHz*)
1)
I
max16
[A] 1.7 2.7 4.4 7.8 14.6
Max. standstill current (8 kHz*) I
08
[A] 2.3 3.8 5.9 10.5 19.5
Max. standstill current (16 kHz*) I
016
[A] 1.7 2.7 4.4 7.8 14.6
Motor voltage U
M
[V] 0-3× U
Mains
Power loss (operation with I
rx
) P
loss
[W] 100 110 140 200 260
Weight m[kg] 3.5 3.5 5.0 5.0 7.5
1)
The currents apply to a periodical load cycle with 1 minute overcurrent with the current mentioned here and
2 minutes base load with 75% I
rx
2)
When operated under rated load, the controller can supply this power additionally.
*