Installation
Electrical installation
4.2.14 Connection of the master frequency input (X9) / master frequency output (X10)
4-52
L
EDSVS9332S-B EN 3.0
4.2.14 Connection of the master frequency input (X9) / master frequency output
(X10)
Note!
Lenze recommends to use prefabricated Lenze cables for the connection to the
master frequency input (X9) or master frequency output (X10).
Ensure that the cores of other cables are twisted in pairs and shielded
(A, A
/B,B/Z,Z) (see wiring diagram).
Features of the master frequency output X10 Features of the master frequency input X9
• 9-pole Sub-D socket
• Output frequency: 0 ... 500 kHz
• Current capacity per channel: max 20mA.
• Two-track with inverse 5 V signals (RS422) and zero track
• X10 has a different basic setting depending on the selected configuration (C0005)
– Lenze setting: Actual speed value
• Load capacity:
– In case of a parallel connection maximally three slave drives can be connected
• LOW level at X10/8 (enable) indicates the initialisation of the master drive (e. g.
when the mains has been switched off in the meantime). This enables the slave
drivetomonitorthemaster.
• 9-pole Sub-D socket
• Can also be used as incremental encoder input
• 0 ... 500 kHz input frequency
• Current consumption per channel: max. 6 mA
• Two-track with inverse 5 V signals and zero track
• Possible input signals:
– Incremental encoder with two 5V complementary signals shifted by
90° (TTL encoder)
– Encoder simulation of the master
• Evaluation of the input signals via C0427
• X9/8 serves to monitor the upstream controller. This requires the
monitoring SD3 to be active.
– In the event of LOW level at X9/8 TRIP or warning (SD3) is activated.
– If the monitoring is not required, this input can be connected to +5V.
B
B
Enable
Lamp
control
GND
GND
Z
Z
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9
A
A
X9X10
l = max. 50 m
0.14 26
0.5
0.5
0.14
0.14
26
26
Æ
AWG
20
20
A
A
A
A
mm
2
B
Z
B
B
B
Z
Z
Z
9300VEC019
Fig. 4-29 Connection of master frequency input (X9) / master frequency output (X10)
X10 Master drive X9 Slave drive c Signals during clockwise
rotation
Assignment of the 9-pole Sub-D socket (X10) at the controller
Assignment of the 9-pole Sub -D socket (X9) at the controller
Pin 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9
Signal B A A +5 V GND1 Z Z EN B B A A +5 V GND1 Z Z LC B