Evaluation of the input signals
Code Function
C0427 = 0
Clockwise rotation Track A leads track B by 90 ° (positive value a t DFIN-OUT)
Counter-clockwise rotation Track A lags track B by 90 ° (negative value at DFIN-OUT)
C0427 = 1
Clockwise rotation Track A transmits the speed
Track B = LOW (positive value at DFIN-OUT)
Counter-clockwise rotation Track A transmits the speed
Track B = HIGH (negative value at DFIN-OUT)
C0427 = 2
Clockwise rotation Track A transmits the speed and direction of rotation (positive value at DFIN-OUT)
Track B = LOW
Counter-clockwise rotation Track B transmits the speed and direction of rotation (negative value at DFIN-OUT)
Track A = LOW