Function library
Code table
9-253
l
EDSVS9332S-D12 EN 3.0
Part D1.2
9.4 Code table
How to read the code table:
Column Abbreviation Meaning
Code C0039
1
2
...
14
15
Code C0039
Subcode 1 of code C0039
Subcode 2 of code C0039
...
Subcode 14 of code C0039
Subcode 15 of code C0039
[C0005] Parameter value of the code can only be modified when the controller is inhibited
LCD Keypad LCD
Lenze Default setting of the code
Æ The column ”Important” contains further information
Codes only display values. They cannot be configured.
Selection 1{1%}99Minimum value {smallest step/unit} maximum value
Important - Additional, important explanation of the code
Printed in bold: Code number in GDC
9-253 Referenceonpagewithfurtherinformationonthecode.
Code Possible settings Important
No. LCD Lenze Selection
[C0002] PAR LOAD 0
Load parameter set
0 Default setting Load default setting into RAM
1
2
3
4
Load parameter set 1
Load parameter set 2
Load parameter set 3
Load parameter set 4
Load parameter set x into the RAM and activate
it
Parameter set 1 is loaded automatically after
every mains connection.
11
12
13
14
Load parameter set 1 externally
Load parameter set 2 externally
Load parameter set 3 externally
Load parameter set 4 externally
Load parameter set x from the keypad into the
RAM and activate it
20 Load parameter sets externally Load all parameter sets from the keypad into
theRAMandactivatethem
C0003 PAR SAVE 0
Save parameter set
0 Executed Saving completed
1
2
3
4
Save parameter set 1
Save parameter set 2
Save parameter set 3
Save parameter set 4
Save current parameter set x non-volatilely
11 Parameter sets → external Transmit all parameter sets to the operating
module
C0004 OP DISPLAY 56 1 {1} 1999 Operating display
Keypad shows selected code in the operating
level if no other status indications of C0183 are
active