EasyManua.ls Logo

Lenze EVS 9300 series - Changing and Saving Parameters

Lenze EVS 9300 series
504 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter setting
Parameter setting using the keypad
7-5
l
EDSVS9332S-D11 EN 3.0
7.2.4 Changing and saving parameters
All parameters for controller setting or monitoring are saved in codes. The codes are numbered and
labelled in the documentation with a C. Some codes store the parameters in numbered
subcodes”, so that a clear parameter setting is ensured (e. g.: C0517 User menu).
The codes are described in detail in the system manual of the drive controller.
Note!
Your settings act on the current parameters in the RAM. You have to save your
settings as parameter set, otherwise they will be lost after mains switching!
If you need only one parameter set, save the settings as parameter set 1, as
parameter set 1 will be loaded automatically after every mains switching of the basic
controller.
Step Keys Action
1. Select menu

Select the desired menu with arrow keys
2. Change to the code level
Display of first code in the menu
3. Select code or subcode

Display of current parameter value
4. Change to parameter level
p
y
p
5. If SHPRG is displayed, inhibit controller
The drive is idling
6.
Change parameters
A)

Move cursor under the digit to be changed
B)

Change digit
)


Change digit quickly
7.
Accept changed parameter
Display of SHPRG or SHPRG

Confirm change to accept parameter
Display ”OK”
Display - The parameter was accepted immediately
8. If necessary, enable controller
The drive should be running again
9.
Change to the code level
A)
Display of operation level
B)
Display of the code with changed parameters
10. Change further parameters Restart the ”loop” at step 1. or step 3.
11.
Save modified parameters
A)

Select code C0003 ”PAR SAVE in the menu ”Load/Store”
B)
Change to parameter level
Display ”0” and ”Ready”
Select parameter set in which the parameters are
to be saved permanently.
C)
Save as parameter set 1
Ö Set ”1” ”Save PS1”
t
o
b
e
s
a
v
e
d
p
e
r
m
a
n
e
n
t
l
y
.
Save as parameter set 2:
Ö Set ”2” ”Save PS2”
Save as parameter set 3:
Ö Set ”3” ”Save PS3”
Save as parameter set 4:
Ö Set ”4” ”Save PS4”
D)

When ”OK” is displayed the settings are saved non-volatile in the selected
parameter set.
12.
Change to the code level
A)
Display of operation level
B)
Display C0003 ”PAR SAVE”
13. Set parameters for different parameter set Restart ”loop” at step 1. or step 3.

Table of Contents

Related product manuals