4.2.15 System bus connection (CAN) (X4)
4-54
L
EDSVS9332S-B EN 3.0
4.2.15 System bus connection (CAN) (X4)
Features
The integrated system bus in the 9300 controller serves to extend the controller functions. These are:
z Parameter selections
z Extensions by decentralised terminals
z Data exchange from controller to controller
z Operator and input devices
z External control and host systems
Without having any experience with thebus system, the user is able to carry out e. g. a dataexchange
from one controller to another with digital control signals, speed signals, and torque signals. If the
user knows how to configure the function blocks this can be done with the help provided in chapter
”Working with function blocks”.
Five input channels and five output channels are available for data exchange and can be used
independently. Two parameter channels are included (SDO = Service Data Object).
General data and application conditions
Communication profile Based on CANopen (parts of CANopen are used)
Communication medium DIN ISO 11898
Network topology Line
System bus node Master or slave
Max. number of nodes 63
Baud rate [kbit/s] 50 125 250 500 1000
Max. bus length [m] 1000 550 250 120 25
Electrical connection Pluggable screw terminals
Communication times
The communication times of the system bus depend on
z data priority
z bus load
z data transmission speed
z processing time in the controller
Telegram runtimes Processing times in the controller
Baud rate [kbits/s] Parameter channel Process data
50 125 250 500
Runtime/processing time [ms] 2.6 1.04 0.52 0.26 <20 1 ... 2